A powerful non corrosive solvent to break down deposits .

 

Directions for Use and Dose Rates

1. Isolate the oil supply disconnect the heat exchanger oil inlet and outlet ,drain off any remaining oil.
2. Connect the discharge side of a portable pump to the lower heat exchanger connection and the suction side of the pump to the bottom outlet of a 200 liter drum.
3. Complete the circuit by connecting the upper connection on the heat exchanger to the top of the
drum.
4. Add carbon Remover to the drum and heat maintaining the temperature (max 50ºC) throught the
cleaning operation. If heating is not available the cleaning time will need to be extended
5. Circulate for 12 hours. When the cleaning is complete disconnect the lower heat exchanger connection
and drain.
6. Connect a high pressure fresh water supply to the upper heat exchanger connection and drain
7. Disconnect ,drain and dry.